Exp Terms panel

The Deconvolution object assumes a unit impulse response function (UIR) of the form:

Phoenix_UserDocs_Deconvolution_Object_image1789

where N is the number of exponential terms.

Use the Exponential Terms panel to enter values for the A and alpha parameters. For oral administration, enter values such that:

Phoenix_UserDocs_Deconvolution_Object_image1791

Required input is highlighted orange in the interface.

None: Columns mapped to this context are not included in any analysis or output.

Sort: Categorical variable(s) identifying individual data profiles.

Parameter: Data variable(s) to include in the output worksheets.

Value: A (coefficients) and Alpha (exponential) parameter values.

A and alpha parameters are listed sequentially based on the number of exponential terms selected. If only one exponential term is selected, each profile has an A1 and an Alpha1 parameter. If two exponential terms are selected, each profile has an A1 and an A2 parameter, and an Alpha1 and an Alpha2 parameter.

Rules for using an external exponential terms worksheet:

The sort variables must match the sort variables used in the main input dataset.

The worksheet’s parameter column must match the number of exponential terms selected in the Exponential Terms menu. For example, if three exponential terms are selected, then each profile in the exponential terms worksheet must have three A parameters and three alpha parameters.

The units used for the A and alpha parameters must match the units used for the concentration and dosing data. For example, If the concentration data has units ng/mL and the dosing data has units mg, then the A units must be ng/mL/mg, or the input data or dosing data should be converted (using Data Wizard Properties) to have consistent units. If the time units are hr, then the alpha units are 1/hr.

If the UIR parameters are unknown but a dataset is available that represents the impulse response, the parameters can be estimated by fitting the data in Phoenix with PK model 1, 8, or 18 (for N=1, 2, or 3, respectively). Since the UIR is the response to one dose unit, for model 1 (one-compartment), the inverse of the model parameter V is used for the UIR parameter, i.e., A1=1/V. For model 8 (two-compartment), the model parameters A and B should be divided by the stripping dose to obtain A1 and A2 for the UIR, and similarly for model 18 (three-compartment). However, if the dose units are different than the concentration mass units, the ‘A’ parameters must be adjusted so that the units are in concentration units divided by dose units. For the example in the prior bullet, if A=1/V from model 1 has units 1/mL, then ‘A’ must be converted to ng/mL/mg before it is used for the UIR in the Deconvolution object, A=10^6/V.


Legal Notice | Contact Certara
© Certara USA, Inc. All rights reserved.