Pharmacodynamic models

When pharmacological effects are seen immediately and are directly related to the drug concentra­tion, a pharmacodynamic model is applied to characterize the relationship between drug concentra­tions and effect. Phoenix includes the following PD models:

Notation definitions 

Emax: Maximum drug effect.
Imax: Maximum drug inhibition.
E0: Baseline effect (effect at C=0).
EC50: Concentration in plasma that achieves 50% of predicted maximum effect in an Emax model.
IC50: Drug concentration required to produce 50% of the maximal inhibition.
Rmax: Effect at infinity (includes maximum drug effect/inhibition and baseline).
F_Emax: Fractional change in effect from baseline E0 
Gamma: Shape parameter

Model 101: Simple Emax model.

PD101.png
pdmodelcalc00580.png 

Estimated parameters: Emax, EC50 

Effect = 0 at C=0 and Emax at C=infinity

Model 102: Simple Emax model with a baseline effect parameter.

PD102.png
pdmodelcalc00582.png 

Estimated parameters: Emax, EC50, E0 

Secondary parameters: Rmax=Emax+E0, F_Emax=Emax/E0 

Effect = E0 at C=0 and Emax + E0 at C=infinity

Model 103: Inhibitory effect model.

PD103_1.png
pdmodelcalc00584.png 

Estimated parameters: E0, IC50 

Effect = 0 at C=0 and Emax at C=infinity

Model 104: Inhibitory effect model with a baseline effect parameter.

PD104.png
pdmodelcalc00586.png 

Estimated parameters: Imax, IC50, E0 

Secondary parameters: Rmax=E0 – Imax, F_Imax=Imax/E0 

Effect = E0 at C=0 and E0 – Imax at C=infinity

Model 105: Sigmoid Emax model.

PD105.png
pdmodelcalc00588.png 

Estimated parameters: Emax, EC50, Gamma

Effect = 0 at C=0 and Emax at C=infinity

Model 106: Sigmoid Emax model with a baseline effect parameter.

PD106.png
pdmodelcalc00590.png 

Estimated parameters: Emax, EC50, E0, Gamma

Secondary parameters: Rmax=Emax+E0, F_Emax=Emax/E0 

Effect = E0 at C=0 and Emax + E0 at C=infinity

Model 107: Sigmoid inhibitory effect model.

PD107.png
pdmodelcalc00592.png 

Estimated parameters: E0, IC50, Gamma

Effect = E0 at C=0 and 0 at C=infinity

Model 108: Sigmoid inhibitory effect model with a baseline effect parameter.

PD108.png
pdmodelcalc00594.png 

Estimated parameters: Imax, IC50, E0, Gamma

Secondary parameters: Rmax=E0 – Imax, F_Imax=Imax/E0 

Effect = E0 at C=0 and E0 – Imax at C=infinity