The number of constants in the model corresponds to the dosing route for the model.
Bolus and first-order input models require at least three dosing constants per profile.
Constant |
Description |
CON[0] |
Number of doses (N) |
CON[1] |
Dose amount for dose N |
CON[2] |
Time of dose for dose N |
CON[3] |
Dose amount for dose N+1 (if multiple doses are used) |
CON[4] |
Time of dose for dose N+1 (if multiple doses are used) |
Constant IV infusion models require at least four dosing constants per profile.
Constant |
Description |
CON[0] |
Number of doses (N) |
CON[1] |
Dose amount for dose N |
CON[2] |
Start time for dose N |
CON[3] |
End time for dose N |
CON[4] |
Dose amount for dose N+1 (if multiple doses are used) |
CON[5] |
Start time for dose N+1 (if multiple doses are used) |
CON[6] |
End time for dose N+1 (if multiple doses are used) |
Last modified date:6/26/19